Specifications Table-top

Specifications Table-top

 Model   AGS-10kNXD  AGS-20kNXD  AGS-50kNXD
Max. Load Capacity   10kN  20kN  50kN
Lineup of Models Differing by
Load Cell Capacity
1N /2N /5N /10N /20N /50N
100N /500N 
1kN/ 5kN / 10kN
20kN 50kN
 Loading Method Direct high-precision constant speed strain control method via non-backlash ball-screw drive Direct, high-precision, constant-rate strain control using non-backlash precision ball-screw drive
Force
Measurement

 
 
Accuracy
 
High-Precision Type
(1/500, ±0.5%)
Within ±0.5% indicated test force (at 1/500 to 1/1 load cell rating)
 
Conforms to EN 10002-2 Grade 0.5, ISO 7500-1 Class 0.5, 
BS 1610 Class 0.5, and ASTM E4, JIS B7721 Class 0.5.*1
Standard-Precision Type
(1/500, ±1%)
 Within ±1% indicated test force (at 1/500 to 1/1 load cell rating)  

Conforms to EN 10002-2 Grade 1, ISO 7500-1 Class 1, 
BS 1610 Class 1, and ASTM E4, JIS B7721 Class 1. *1
 Calibration  Automatic test force calibration: select tensile, compression, or 
tensile and compression  
 Crosshead 
  
Speed Range  0.001 to 1000 mm/min (stepless)  0.001 to 1600 mm/min (stepless)  0.001 to 800 mm/min (stepless)
Max. Return Speed  1500mm/min  2200mm/min  1100mm/min
 Crosshead Speed
 Accuracy *2  
 ±0.1%  
 Crosshead Speed and
Permitted Test Force  
 To load cell capacity across entire speed range  
 Crosshead - Table 
Distance 
(Tensile stroke) *3
1200mm 
(760mm, MWG)
 1250mm 
(765mm, MWG)
 1210mm
(745mm, MWG)
 Effective Test Width    425mm  
Crosshead
Position
Detection
 Measurement Method   Optical encoder  
 Display Method   Digital display (display resolution: 0.001 mm)  
Positional Accuracy   ±0.1% indicated value or ±0.01 mm, whichever is larger 
 Sampling Speed    1000Hz max. *4  
 Standard Functions
 • Automatic reading of load cell characteristic values
 • Test force display, stress display, stroke display,position display
 • External analog output (2 channels)
 • External analog input (2 channels) *4
 • External digital input (2 channels) *4
 • Analog recorder (option) output
 • Dataletty (option) output *5
 • Automatic test force / stress control (Autotuning)
 • Automatic strain control (Autotuning) *4
 • Test force auto-zeroing
 • Test force auto-calibration
 • Break detection, auto-return
 • Load cell overload detection
 • Touch-load detection function
 Accessories 
Load cell (with CAL cable), Power cable (2.5 m), turning rod, cable clamps, instruction manual
Load Cell (with CAL cable), Power cable (5 m), turning rod, cable clamps, instruction manual
Load Cell (with CAL cable), Power cable (5 m), turning rod, cable clamps, instruction manual
 Dimensions
653×D520×H1603mm
W718×D641×H1633mm
W718×D641×H1633mm
 Weight    85kg  235kg  260kg
 Power Requirements
Single phase 100/120/220/240 V AC
(switching type) 50/60 Hz 1.2 kVA
 Single phase AC200-230V 50/60Hz 4.0kVA 
Supply voltage fluctuations within ±10% of the set value.
D-class (100 Ω max.) grounding resistance.
 Operating Environment  
 Temperature: 5 °C to 40 °C; Humidity: 20% to 80% (no condensation)
Floor vibrations: frequency 10 Hz max., amplitude 5 μm max.
*1 Official certification after installation is recommended to comply with EN 10002-2, ISO 7500-1, and ASTM E4 standards, JIS B7721.
*2 Crosshead speed accuracy is calculated from the crosshead travel within a prescribed time at a constant speed between 0.5 mm/minute and 500 mm/minute.
*3 The tensile stroke is the effective stroke when SCG (screw-type flat grips) or MWG (non-shift wedge-type grips) are mounted.
*4 TRAPEZIUM X or TRAPEZIUM LITE X is needed for these functions. Moreover, when automatic test force/stress control (auto tuning) and the automatic strain control (auto tuning) are used, the sampling speed becomes 10msec.
*5 Dataletty (option) and TRAPEZIUM X / TRAPEZIUM LITE X can not be used together.
* Values stated in this catalog are based on measurements conducted according to separately defined inspection standards.
* Windows7/ Windows Vista/ Windows XP is a registered trademark in the United States and other countries of Microsoft Corporation.
 

This page may contain references to products that are not available in your country.
Please contact us to check the availability of these products in your country.

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.